Wang NMR Inc.
Home     Products    Sales    Employment    Newsroom   Contact

 NMR  MRI  MRS Superconducting

Superconducting NMR Magnet Systems
Products:
1.  JupiterTM NMR 200-300 MHz Spectrometer System Specification
2.  JupiterTM NMR 400-600 MHz NMR Console Specification
3.  JupiterTM High Resolution NMR Spectrometer
4.  H-Spectrum from Bone Marrow

Wang NMR Inc.'s NMR Magnet Specifications

Model NO. *

600/54 500/89 500/54
300/54
360/54
400/54
300/89
360/89
400/89
100/54
200/54
270/54
100/89
200/89
270/89
100/110
200/110
270/110
100/130
200/130
270/130
Room Temperature   
Bore Diameter (mm)
53.8 88.1 53.8 53.8 88.1 53.8 88.1 110.9 136.4
Helium Hold Time (days) 120 120 120 120 120 180 180 180 180
Nitrogen Hold Time (days) 14 14 14 14 14 14 14 14 14
Cylindrical Sample Size Diameter (mm) X Length (mm) 10x20 20x20 10x20 10x10 20x20 10x10 20x20 25x25 25x25
Resolution With Supercon Shim 0.1 0.2 0.1 0.1 0.2 0.1 0.2 0.5 0.5
Resolution with Supercon and RT Shims 0.01 0.02 0.01 0.01 0.02 0.01 0.02 0.05 0.05
Resolution with Supercon RT Shims and Sample Spinning 0.001 0.002 0.001 0.001 0.002 0.001 0.002 0.005 0.005
Field Stability (ppm/hr) 0.03 0.03 0.003 0.01-0.03 0.01-0.03 0.01 0.01 0.01 0.01
*  Other special custom-made model available on request. Please send email to Sales Department.
¡@

WANG NMR INC. ACTIVELY SHIELDED HIGH RESOLUTION
NMR MAGNETS FOR VERTICAL BORE SYSTEM

Frequency /

  Nominal bore (mm)

200/40

200/51

 

200/89

300/40

300/51

 

300/89

400/40

400/51

 

400/89

500/40

500/51

 

500/89

600/40

600/51

 

600/89

Room Temperature Bore (mm)

  51.0

88.9

51.0

88.9

51.0

88.9

51

88.9

51

88.9

Standard

-

-

-

-

-

-

-

-

-

-

Minimum Helium Hold time (days)

180

180

180

180

180

180

180

180

180

180

Cryogen Free

-

-

-

-

-

-

-

-

-

-

Minimum Nitrogen Hold Time (days)

18

18

18

18

18

18

18

18

18

18

Homogeneity Volume  dia. (mm) X Length (mm)

10 X 20

20 X 20

10 X 20

20 X 20

10 X 20

20 X 20

10 X 20

20 X 20

10 X 20

20 X 20

Homogeneity Specification with Supercon Shim

0.1

0.2

0.1

0.2

0.1

0.2

0.1

0.2

0.1

0.2

With Supercon/RTShim

0.01

0.02

0.01

0.02

0.01

0.02

0.01

0.02

0.01

0.02

With Supercon /RTShim/Spinning

0.001

0.002

0.001

0.002

0.001

0.002

0.001

0.002

0.001

0.0012

Spinning Side Bands for Carbon 13, Less than

 

1%

 

1%

 

1%

 

1%

 

1%

 

1%

 

1%

 

1%

 

1%

 

1%

Field Stability Hz/Hr

2

2

3

3

10

10

10

10

10

10


Home | Sales | Products | Newsroom | Employment   

Copyright  2001, Wang NMR, Inc. All Rights Reserved.   For information, send email to  WangNMR
Wang NMR Inc.  550 North Canyons Parkway, CA 94550   Tel: (925) 443-0212  Fax: (925) 443-0215
Last updated:  08/15/02

¡@